B--63003EN--1/02
3. MANUAL OPERATION
300
#7
1002
#6 #5 #4 #3 #2 #1 #0
JAX
[Data type] Bit
JAX Number of axes controlled simultaneously in jog feed, manual rapid
traverse and manual reference position return
0: 1axis
1: 3axes
#7
1401
#6 #5 #4 #3 #2 #1 #0
RPD
[Data type] Bit
RPD Manual rapid traverse during the period from power--on time to the
completion of the reference position return.
0 : Disabled (Jog feed is performed.)
1: Enabled
#7
1402
#6 #5 #4
JRV
#3 #2 #1 #0
[Data type] Bit
JRV Manual continuous feed (jog feed)
0 : Jog feed is performed at feed per minute.
1 : Jog feed is performed at feed per rotation.
NOTE
Specify a feedrate in parameter No. 1423.
1423 Feedrate in manual continuous feed (jog feed) for each axis
[Data type] Word axis
(1)In M series, or in T series when JRV, bit 4 of parameter No. 1402, is
set to 0 (feed per minute), specify a jog feedrate at feed per minute with
an override of 100%.
Increment system Unit of data Valid data range
Millimeter machine 1 mm/min
Inch machine 0.1 inch/min
6 -- 32767
Rotation axis 1 deg/min
(2)When JRV, bit 4 of parameter No. 1402, is set to 1 (feed per revolution)
in T series, specify a jog feedrate (feed per revolution) under an
override of 100%.
Increment system Unit of data Valid data range
Millimeter machine 0.01 mm/rev
Inch machine 0.001 inch/rev
0 -- 32767
Rotation axis 0.01 deg/rev
Parameter
[Unitofdata]
[Valid data range]
[Unitofdata]
[Valid data range]