B--63003EN--1/02
3. MANUAL OPERATION
297
[Operation] When the signal is high, the control unit operates as described below.
D When jog feed or incremental feed is allowed, the control unit moves
the specified axis in the specified direction.
D In jog feed, the control unit continues to feed the axis while the signal
is “1”.
Jog mode
(or Teach in jog mode)
+J1
1st axis move
D In incremental feed, the control unit feeds the specified axis by the step
distance which is specified by the manual handle feed move distance
selection signal MP1, MP2. Then the control unit stops it. Even if the
signal is set to “0” while the axis is being fed, the control unit does not
stop feeding it.
To feed the axis again, set the signal to “0”, then set it to “1” again.
Incremental feed mode
(TEACHINHANDLE
mode)
+J1
1st axis move
NOTE
1 If both the positive direction and negative direction signals
of the same axis are simultaneously set to “1”, neither the
positive direction nor the negative direction is selected. The
control unit assumes that both these signals are set to “0”.
2 If the feed axis and direction selection signals are set to “1”
before the jog feed mode or incremental feed mode is
selected, these signals are invalidated. After the jog feed
mode or incremental feed mode is selected, set these signal
to “0”, then set them to “1” again.
3 If the control unit is reset while the feed axis and direction
selection signals are set to “1” or if a feed axis and direction
signal turns to “1” while the control unit is in the reset state,
the signal cannot be validated by releasing the reset state.
After the reset state is released, set these signals to “0”,
then set them to “1” again.
Jog mode
or incremental feed mode
+J1
1st axis move
+J1 is inef-
fective dur-
ing this
period.
Axis is fed again after signals
have turned to “0” once.