B--63003EN--1/02
4. REFERENCE POSITION ESTABLISHMENT
379
(3)Perform reference position return again. Then, the tool stops when it
reaches the reference position.
|
Direction of reference position return
Deceleration dog
|
Reference position
(stop position)
Grid point
|
|
|
L
SFT
#7
1002
#6 #5 #4 #3 #2
SFD
#1 #0
[Data type] Bit
SFD The function for shifting the reference position is
0: Notused
1: Used
1850 Reference position shift for each axis
[Data type] Two--word axis
[Unitofdata] Detection unit
[Valid data range] --99999999 to 99999999
A reference position shift is set for each axis.
CAUTION
When bit 2 of parameter No. 1002, SFD, is set to 0, this
parameter is used for reference position shift.
NOTE
When this parameter has been set, the power must be
turned off before operation is continued.
Parameter