2/2
PAGE
EDT.
DATE
DESIGN
DESCRIPTION
TITLE
No.
16
i
/18
i
/21
i
/20
i
/160
i
/180
i
/210
i
-MODEL A
16
i
/18
i
/21
i
/160
i
/180
i
/210
i
-MODEL B
CONNECTION MANUAL (FUNCTION)
Explanation change of “Rigid tapping”
B-63003EN-1/02-13, B-63523EN-1/01-6
01 01.10.25 Newl
Re
istered
9.11.7.4 Timing to cancel rigid tapping mode
The explanation of “9.11.7.4 Timing to cancel rigid tapping mode” is changed as follows.
( before change )
The spindle output is produced in the same way as executing S0. Cancel the PMC rigid
tapping mode at the falling edge of the ENB signal (ENB2 signal for 2
nd
spindle of T series)
by de-energizing the spindle, then turn off the rigid tapping mode signal.
( after change )
The S command which is used at rigid tapping is cleared automatically at canceling the rigid
tapping mode and the condition becomes the same that S0 is commanded. By this, as the
spindle output becomes 0, cancel the PMC rigid tapping mode at the falling edge of the ENB
signal (ENB2 signal for 2
nd
spindle of T series) by de-energizing the spindle, then turn off the
rigid tapping mode signal.