16. INTERFACES RELATED TO Series 20i MACRO
B--63003EN--1/02
1290
Limit data setup signals
Address Set data
R961 4: Specifies a line. 5: Specifies a limit condition.
R962 to R965 Line tilt (COS° × 2
30
) Inner datum point coordinate first
axis
R966 to R969 Line tilt (SIN° × 2
30
) Inner datum point coordinate se-
cond axis
R970 to R973 Distance from the origin
to the line
--
R974 Line number (0 to 5) --
R970 -- Number of lines (1 to 6)
R971 -- Outside/inside the limit area
0: Outside forbidden
1: Inside forbidden
R976 -- Plane selection
Lower 4 bits: Plane first axis
Upper 4 bits: Plane second axis
1: X--axis
2: Y--axis
3: Z--axis
R978 Setup change notification Setup change notification
#7
R940
#6 #5 #4 #3 #2 #1 #0
MLMRQ
Polygon limit mode request signal
MLRQ: MACRO requests the PMC to switch tothe polygonlimit
mode.
#7
G0089
#6 #5 #4 #3 #2 #1 #0
MALMT
Polygon limit enable/disable signal
MALMT: When this signal 1, it enables the polygon limit.
16.2
SIGNALS USED FOR
POLYGON LIMIT
MACHINING (20i-- F A )
MACRO → PMC
MACRO → PMC
PMC → CNC