4. REFERENCE POSITION ESTABLISHMENT
B--63003EN--1/02
398
JOG
ZRN
+J1
Reference mark
ZRF1
Feedrate
FL feedrate FL feedrate FL feedrate
Fig. 4.8 (b) Time chart for reference position establishment
#7
1815
#6 #5 #4 #3 #2
DCLx
#1
OPTx
#0
[Data type] Bit axis
OPTx As a position detector:
0 : A separate pulse coder is not used.
1 : A separate pulse coder is used.
(To use a linear scale with absolute addressing reference marks, set this bit
to 1.)
DCLx As a separate position detector:
0 : A linear scale with absolute addressing reference marks is not used.
1 : A linear scale with absolute addressing reference marks is used.
#7
1802
#6 #5 #4 #3 #2 #1
DC4
#0
[Data type] Bit
DC4 When establishing the reference position using the linear scale with
absolute addressing reference marks:
0 : Three referencemarks are detected to determinethe absoluteposition.
1 : Four reference marks are detected to determine the absolute position.
1821 Reference counter capacity for each axis
[Data type] 2--word axis
[Unitofdata] Detection units
[Valid data range] 0 to 99999999
Sets the intervals of mark 1 of the linear scale with absolute addressing
reference marks.
Parameter