B--63003EN--1/02
2. PREPARATIONS FOR OPERATION
280
[Classification] Output signal
[Function] Informs the PMC that an abnormal load was detected on a servo axis.
[Output condition] This signal becomes “1” if:
S An abnormal load is detected for a servo axis, Cs axis, spindle
positioning axis, or spindle axis during rigid tapping.
[Classification] Output signal
[Function] Informs the PMC that an abnormal load was detected on the first axis.
[Output condition] This signal becomes “1” if:
S An abnormal load is detected for the first spindle under speed control.
[Classification] Output signal
[Function] Informs the PMC that an abnormal load was detected on the second axis.
[Output condition] This signal becomes “1” if:
S An abnormal load is detected for the second spindle under speed
control.
The following list summarizes the alarms and signals output by each
function.
Signal output Alarm
ABTQSV ABTSP1/
ABTSP2
409 754/764
Servo axis f — f —
Cs contour control f — f —
Spindle positioning axis f — f —
Rigid tapping f — — f
Spindle axis for speed control — f — f
Signal
Servo axis abnormal
load detected signal
ABTQSV <F090#0>
First--spindle abnormal
load detected signal
ABTSP1 <F090#1>
Second--spindle
abnormal load detected
signal ABTSP2 <F090#2>