14. MEASUREMENT
B--63003EN--1/02
1194
[Classification] Input signal
[Function] Selects the mode forwriting the shift amount for the workpiece coordinate
system.
[Operation] When this signal is turned “1” in a manual operation mode, the mode for
writing the shift amount for the workpiece coordinate system is selected.
The control unit then automatically switches the screen displayed to the
WORK SHIFT screen and blinks the “OFST” status display in the bottom
of the screen to notify that the mode has been changed to the mode for
writing the shift amount for the workpiece coordinate system. However,
this is not performed when the mode for writing tool compensation values
is selected.
[Classification] Input signal
[Function] Automatically calculates and sets the shift amount for the workpiece
coordinate system.
[Operation] When this signal turns to “1” in the mode for writing the shift amount for
the workpiece coordinate system, it triggers automatic calculation and
setting of the shift amount for the workpiece coordinate system.
#7
X004
#6 #5
-- M I T 2
SKIP5
#4
+MIT2
SKIP4
#3
-- M I T 1
SKIP3
#2
+MIT1
SKIP2
#1 #0
WARNING
Since the same addresses are used for both +MIT1, --MIT1,
+MIT2, -- MIT2 and skip signals SKIP2 to SKIP5 (multi-- step
skip), be careful for using two kinds of signals.
#7
GOQSMG039
#6
WOQSM
#5
OFN5
#4
OFN4
#3
OFN3
#2
OFN2
#1
OFN1
#0
OFN0
WOSETG040 OFN6
Workpiece coordinate
system shift value write
mode select signal
WOQSM <G039#6>
Workpiece coordinate
system shift value write
signal
WOSET <G040#7>
Signal address