FANUC Series 16i/18i/21i/20i/160i/180i/210i-MODEL A
CONNECTION MANUAL (FUNCTION)
Concerning the addition of
PMC axis control expansion
B-63003EN-1/02-12
01 01.10.23 Newl
Re
istered
Step 2 : Cutting feed - sec/block for A group and C group
EC0A ~ EC6A = 00100001(21H) EC0C ~ EC6C = 00100001(21H)
EIF0A ~ EIF7A = 00110010(32H) EIF0C ~ EIF7C = 00110010(32H)
EIF8A ~ EIF15A = 00000000(00H) EIF8C ~ EIF15C = 00000000(00H)
EID0A ~ EID7A = 01000000(40H) EID0C ~ EID7C = 01010000(50H)
EID8A ~ EID15A = 00001101(0DH) EID8C ~ EID15C = 11000011(C3H)
EID16A ~ EID23A = 00000011(03H) EID16C ~ EID23C = 00000000(00H)
EID24A ~ EID31A = 00000000(00H) EID24C ~ EID31C = 00000000(00H)
Simultaneous start mode ON or OFF block can be commanded on any path. If another
simultaneous start mode ON is commanded in simultaneous start mode ON, the block is to be
ignored.
The paths which are not specified for simultaneous start mode can be commanded normally.
- Notes
(1)
Reset signal (ECLRg), Buffering disable signal (EMBUFg), Servo-off signal (ESOFg) and
Auxiliary function completion signal (EFINg) are effective independently for each path in
simultaneous start mode ON.
(2)
Axis control temporary stop signal (ESTPg) is effective for all simultaneous paths.
When this signal is set to “1” on any path, all axes which are specified for simultaneous
start mode decelerate and stop.
(3)
Block stop signal (ESBKg) is effective for all simultaneous paths.
When this signal is set to “1” on any path, all axes which are specified for simultaneous
start mode stop after the blocks being executed are completed.
However, when Block stop disable signal (EMSBKg) is set to “1” on any path which is
specified for simultaneous start mode, Block stop signal (ESBKg) is disabled.
(4)
When simultaneous start mode ON is commanded, please confirm that Buffer full signals
(EABUFg) for specifying paths are “0”.
(5)
When the path which has no axis by specifying Control axis selection signals (EAX1 ~
EAX8) is selected by simultaneous start mode ON, please turn Axis control command
read signal (EBUFg) for that path, otherwise simultaneous start is not executed.