4. REFERENCE POSITION ESTABLISHMENT
B--63003EN--1/02
394
[Classification] Output signal
[Function] These signals are used to post notification of the torque limit having been
reached for each corresponding axis during cycle operation for butt--type
reference position setting.
[Operation] Each signal is set to 1 when:
· The torque limit is reached for the corresponding axis during cycle
operation for butt--type reference position setting.
Each signal is set to 0 when:
· The torque limit is not reached for the corresponding axis during cycle
operation for butt--type reference position setting.
#7
CLRCH8F180
#6
CLRCH7
#5
CLRCH6
#4
CLRCH5
#3
CLRCH4
#2
CLRCH3
#1
CLRCH2
#0
CLRCH1
#7
1006
#6 #5
ZMIx
#4 #3 #2 #1 #0
NOTE
When this parameter is changed, turn off the power before
continuing operation.
[Data type] Bit axis
ZMIx The direction of reference position return and the direction of initial
backlash at power--on.
0 : Positive direction
1 : Negative direction
7181 First withdrawal distance in butt--type reference position setting
[Data type] 2--word axis
Increment system IS--A IS--B IS--C Unit
Millimeter machine 0.01 0.001 0.0001 mm
Inch machine 0.001 0.0001 0.00001 inch
Signal
Torque limit reach
signals for butt--type
reference position
setting CLRCH1 to
CLRCH8 <F180>
Signal address
Parameter
[Unitofdata]