B--63003EN--1/02
7. FEEDRATE CONTROL/ACCELERATION
AND DECELERATION CONTROL
614
NOTE
1 The settings must satisfy the relationship D1 < D2 < D3 < D4
<D5<D6.
2 Up to seven levels can be used for adjustment. When using
four levels, for example, set D4 to 99999999.
3 For diameter programming axes, set a diameter. For
example, assume that 10.000 mm is set in a parameter for
diameter programming axes. Then, when the amount of
travel has reached 10.000 mm, adjustment is performed.
6161 Level 1 rapid traverse rate
6162 Level 2 rapid traverse rate
6163 Level 3 rapid traverse rate
6164 Level 4 rapid traverse rate
6165 Level 5 rapid traverse rate
6166 Level 6 rapid traverse rate
6167 Level 7 rapid traverse rate
[Data type] 2--word
Increment system Unit of data Valid data range
Millimeter machine 1 mm/min 30 to 240000
Inch machine 0.1 inch/min 0 to 96000
The rapid traverse rate for each axis is set.
6171 Level 1 rapid traverse time constant
6172 Level 2 rapid traverse time constant
6173 Level 3 rapid traverse time constant
6174 Level 4 rapid traverse time constant
6175 Level 5 rapid traverse time constant
6176 Level 6 rapid traverse time constant
6177 Level 7 rapid traverse time constant
[Data type] Word axis
[Unitofdata] ms
[Valid data range] 8 to 4000
The rapid traverse time constant for each axis is set.
[Unitofdata]
[Valid data range]