B--63003EN--1/02
14. MEASUREMENT
1199
The ten code signals (binary code) select a tool offset number. Code
signals 0 to 998 correspond to tool offset numbers 1 to 999.
NOTE
This signal is valid only when the QNI bit (bit of 5 parameter
No. 5005) is set to 1.
[Classification] Input signal
[Function] Selects workpiece coordinate system shift measurement mode.
[Operation] When the signal goes “1” in manual operation mode, workpiece origin
offset measurement mode is selected. The screen is automatically
replaced with the workpiece coordinate system setting screen. In the
status display field at the bottom of the screen, “WOFS” blinks to indicate
that workpiece origin offset measurement mode has been selected.
[Classification] Input signal
[Function] Stores the momentary position where the signal goes “1” in the workpiece
origin offset measurement, as a measurement point. At the same time, the
axial movement is stopped.
[Operation] When the skip signal is brought to “1” while the measurement probe is
touching the reference plane or the external edge of the reference hole in
the workpiece origin offset value measurement, the momentary machine
coordinates are stored as the position of the measurement point. At the
same time, the axial movement by manual handle feed or jog feed stops.
Until the skip signal is brought to “0”, the interlock prevents the
movement in the direction in which the measurement probe was brought
to the current measurement point.
#7
SKIPX004
#6 #5 #4 #3 #2 #1 #0
GOQSMG039 WOQSM OFN5 OFN4 OFN3 OFN2 OFN1 OFN0
#7 #6 #5 #4 #3 #2 #1 #0
G040 OFN9 OFN8 OFN7 OFN6
Wo rkpiece origin offset
measurement mode
selection signal WOQSM
<G039, #6>
Skip signal SKIP
<X004, #7>
Signal addresses