B--63003EN--1/02
7. FEEDRATE CONTROL/ACCELERATION
AND DECELERATION CONTROL
598
8400 Parameter 1 for determining a linear acceleration/deceleration before interpolation
[Data type] Two--word
Valid data range
ncrement system
n
to
ata
I S --- A , I S --- B I S --- C
Millimeter machine 1 mm/min 10 -- 60000 1 -- 6000
Inch machine 0.1 inch/min 10 -- 60000 1 -- 6000
Rotation axis 1 deg/min 10 -- 60000 1 -- 6000
This parameter determines a linear acceleration and deceleration before
interpolation. Usually, set the maximum cutting speed (parameter No.
1422).
8401 Parameter 2 for determining a linear acceleration/deceleration before interpolation
[Data type] Word
[Unitofdata] 1ms
[Valid data range] 0 to 4000
This parameter specifies the time required until the speed specified in
parameter 1 is achieved.
NOTE
The function for linear acceleration/deceleration before
interpolation is canceled when either parameter no. 8400 or
8401 is set to 0.
Parameter 1
Speed
Time
Parameter 2
Acceleration
7.1.14.4
Parameter
P arameters of linear accel-
eration and deceleration
before interpolation
[Unitofdata]
[Valid data range]