6. INTERPOLATION FUNCTION
B--63003EN--1/02
502
#7
7602
#6 #5
COF
#4
HST
#3
HSL
#2
HDR
#1
SNG
#0
MNG
[Data type] Bit
MNG The rotational direction of the master axis (first spindle) in the
spindle--spindle polygon turning mode is:
0: Not reversed.
1: Reversed.
SNG The rotational direction of the polygon synchronization axis (second
spindle) in the spindle--spindle polygon turning mode is:
0: Not reversed.
1: Reversed.
HDR When phase control is exercised in spindle--spindle polygon turning
mode (COF = 0), the phase shift direction is:
0: Not reversed for phase synchronization.
1: Reversed for phase synchronization.
NOTE
Use MNG, SNG, and HDR when the specified rotational
direction of the master axis or polygon synchronization axis,
or the specified phase shift direction is to be reversed in
spindle--spindle polygon turning mode.
HSL When phase control is exercised in spindle--spindle polygon turning
mode (COF = 0), this parameter selects the spindle that is subject to a
phase shift operation for phase synchronization:
0: The polygon synchronization axis (second spindle) is selected.
1: The master axis (first spindle) is selected.
HST When phase control is applied in spindle--spindle polygon turning mode
(COF = 0), and spindle--spindle polygon turning mode is specified:
0: Spindle--spindle polygon turning mode is entered with the current
spindle speed maintained.
1: Spindle--spindle polygon turning mode is entered after the spindle is
stopped.
NOTE
This parameter can be used, for example, when
single--rotation signal detection cannot be guaranteed at an
arbitrary feedrate because a separate detector is installed
to detect the spindle single--rotation signal, as when a
built--in spindle is used. (When bit 7 of parameter No. 4016
for the serial spindle is set to 1, together with this parameter,
a single -- rotation signal detection position in
spindle--spindle polygon turning mode is guaranteed.)
Parameter