5. AUTOMATIC OPERAT ION
B--63003EN--1/02
448
Tapping retraction start signal
RTNT
Spindle enable signal ENB
Rigid tapping signal RGTAP
Spindle excitation
Retract movement
When tapping retract is stopped, spindle enable signal ENB is set to “0”,
in the same way as for ordinary rigid tapping. Therefore, perform the
sequence for canceling rigid tapping. The CNC also automatically enters
the reset state when tapping retract is stopped.
[Classification] Input signal
[Function] Starts rigid tapping retraction.
[Operation] When this signal is set to “1”, the control unit operates as follows:
S Starts rigid tapping retraction.
[Classification] Output signal
[Function] Notifies the completion of rigid tapping retraction.
[Output condition] This signal is set to “1” in the following case:
S Rigid tapping retraction has been completed.
This signal is set to “0” in the following case:
S Rigid tapping retraction start signal has been set to “0”.
Time chart for stopping
rigid tapping retraction
Signal
Rigid tapping retraction
start signal RTNT
<G062#6>
Rigid tapping retraction
completion signal RTPT
<F066#1>