B--63003EN--1/02
7. FEEDRATE CONTROL/ACCELERATION
AND DECELERATION CONTROL
619
Others f : Can be programmed
× : Cannot be programmed
Name
Description
Cycle start/Feed hold
f
Dry run
f
Single block
f
Interlock
f
Machine loc k f When an axis machine lock signal (MLK1 to
MLK8) is turned on or off, acceleration/de-
celeration is not performed on the axis held
under machine lock.
Control --in/control--out com-
mand ( )
f
Optional block skip command
(/n: n is a number)
f
Miscellaneous function
(Mxxxx)
f Only the function code signal and function
strobe signal are output.
Spindle function (Sxxxx)
f
Tool function (Txxxx) f Only the function code signal and function
strobe signal are output.
Second auxiliary function
(Bxxxx)
f Only the function code signal and function
strobe signal are output.
Simple synchronous control f Synchronous control cannot be enabled or
disabled.
Program restart
×
Retrace function
×
Tool life management
×
Macro executor
(execution macro)
×
MDI operation × When G05.1 Q1 is specified in MDI mode,
P/S alarm No. 5113 is issued. The operation
mode cannot be switched to MDI mode in
simple high --precision contour control
mode.
Manual intervention
f
Those functions marked with an asterisk (*) do not perform look--ahead
control of multiple blocks.