B--63003EN--1/02
3. MANUAL OPERATION
340
MPX Specifies how the manual handle feed travel distance select signals are to
be used as follows:
0 : The signals (MP1 and MP2; bits 4 and 5 of G019) for the first manual
pulse generator are used for the first to fourth (F series) or third (T
series) pulse generators in common.
1 : Each manual handle feed travel distance select signal is used for an
individual manual pulse generator.
First manual pulse generator: MP1, MP2 (G019#4, G019#5)
Second manual pulse generator: MP21, MP32 (G087#0, G087#1)
Third manual pulse generator: MP31, MP32 (G087#3, G087#4)
Fourth manual pulse generator: MP41, MP42 (G087#6, G087#7)
NOTE
Parameter MPX (bit 5 of No. 7100) is valid only in the Series
20i.
7110 Number of manual pulse generators used
[Data type] Byte
[Valid data range] 1, 2, or 3
This parameter sets the number of manual pulse generators.
7113 Manual handle feed magnification m
[Data type] Word
[Unitofdata] One time
[Valid data range] 1to127
This parameter sets the magnification when manual handle feed
movement selection signal MP2 is on.
7114 Manual handle feed magnification n
[Data type] Word
[Unitofdata] One time
[Valid data range] 1 to 1000
This parameter sets the magnification when manual handle feed
movement selection signals MP1 and MP2 are “1”.