B--63003EN--1/02
13. INPUT/OUTPUT OF DATA
1121
Input/output channel number (parameter No. 0020)
Stop bit and other data
Number specified for the in-
put/output device
Baud rate
Stop bit and other data
Number specified for the in-
put/output device
Baud rate
Stop bit and other data
Number specified for the in-
put/output device
Baud rate
Stop bit and other data
Number specified for the in-
put/output device
Baud rate
Selection of protocol
Selection of RS--422 or
RS--232--C, and other data
I/ O CHANNEL
=0 : Channel1
=1 : Channel1
=2 : Channel2
=3 : Channel3
Specify a channel for an
input/output device.
I/O CHANNEL=1
(channel 1)
0020
0101
0102
I/O CHANNEL=0
(channel 1)
0103
0111
0112
I/O CHANNEL=3
(channel 3)
0113
0121
0122
I/O CHANNEL=2
(channel 2)
0123
0131
0132
0133
0134
0135
I/O CHANNEL
#7
3201
#6
NPE
#5
N99
#4 #3 #2
REP
#1
RAL
#0
RDL
[Data type] Bit
RDL When a program is registered by input/output device external control
0 : The new program is registered following the programs already
registered.
1 : All registered programs are deleted, then the new program is
registered.
Note that programs which are protected from being edited are not
deleted.
RAL When programs are registered through the reader/puncher interface
0 : All programs are registered.
1 : Only one program is registered.
REP Action in response to an attempt to register a program whose number is
the same as that of an existing program
0 : An alarm is generated.
1 : The existing program is deleted, then the new program is registered.
Note that if the existing program is protected from being edited, it is
not deleted, and an alarm is generated.
Parameter