12. DISPLAY/SET/EDIT
B--63003EN--1/02
1074
Automatic erase screen display cancel signal *CRTOF (G062#1) is valid
only for the signals for path 1. This signal is invalid for the signals of path
2 (G1062#1) and those of the loader (G062#1).
If parameter No. 3123 is set to 0, clearing of the screen using the
CAN
key
and a function key is disabled.
The period specified with parameter No. 3123 is valid only for path 1.
The screen is not cleared if an alarm is issued for path 1 or 2 or the loader
before the specified period elapses.
WARNING
Pressing any key while the screen is being cleared restores
the screen. In such a case, however, the function assigned
to the pressed key is initia ted. Do not press the ,, or
key to restore the screen, therefore.
ALTER
INSERTDELETE
[Classification] Input signal
[Function] Enables or disables the automatic screen erase function. This signal is
used to switch the control mode.
[Operation] When this signal is set to 0, the control unit:
· Enables the automatic screen erase function.
When this signal is set to 1, the control unit:
· Disables the automatic screen erase function, displays the screen, and
initializes the timer.
This signal is valid only for path 1.
#7 #6 #5 #4 #3 #2 #1 #0
G062 *CRTO F
D Automatic erase screen
display cancel signal
D Clearing the screen
using + function key
CAN
D Specified period
D Alarm for another path
Signal
Automatic erase screen
display cancel sig n al
*CRTOF <G062#1>
Signal address