B--63003EN--1/02
2. PREPARATIONS FOR OPERATION
291
#7
G016
#6 #5 #4 #3 #2 #1 #0
MSDFON
DSV8Y (n+00 D SV7 DSV6 DSV5 DSV4 DSV3 DSV2 DSV1
#7 #6 #5 #4 #3 #2 #1 #0
Y (n+1) DSP3 DSV2 DSV1
Reserved
1890 Servo motor speed for detection
NOTE
When this parameter has been set, the power must be
turned off before operation is continued.
[Data type] Word axis
[Unitofdata] rpm
[Valid data range] 0 to 8000
The servo motor speed of each axis is monitored and a motor speed
detection signal is output indicating whether the speed of each axis
exceeds the value set in this parameter (set in the Y address specified in
parameter No. 1891)
NOTE
No motor speed detection signals are output when the
servo/spindle motor speed detection function is not used or
0 is set in this parameter.
1891 Initial value of the Y address where motor speed detection signals are output
NOTE
When this parameter has been set, the power must be
turned off before operation is continued.
[Data type] Word axis
[Valid data range] 0 to 126, 1000 to 1013, 1020 to 1033
This parameter specifies the Y address where motor speed detection
signals are output.
The spindle motor speeds and servo motor speed of each axis are
monitored and motor speed detection signals are output to the Y address
Signal address
Parameter