B--63003EN--1/02
3. MANUAL OPERATION
299
[Classification] Input signal
[Function] Selects a rapid traverse rate for jog feed or incremental feed.
[Operation] When the signal turns to “1”, the control unit operates as described below:
D The control unit executes the jog feed or incremental feed at a rapid
traverse rate. The rapid traverse override is validated.
D When the signal is switched from “1” to “0” or vice versa during jog
feed or incremental feed, the feedrate is decelerated until it reaches
zero, then increased to the specified value. During acceleration and
deceleration, the feed axis and direction selection signal can be kept
“1”.
Rapid traverse
rate
Jog feed mode
or incremental feed mode
+J1
RT
1st axis move
Feedrate selected by manual
feedrate override signal
WARNING
After the power is turned on, the stroke limit function does
not work until the reference position return is completed.
During this period, the control unit ignores the RT signal, if
it is set to “1”, and keeps moving the tool at a feedrate
selected by the manual feedrate override signal. A
parameter RPD (No. 1401#0) can be specified so that the
rapid traverse is validated before the reference position
return is completed.
#7
*JV7G010
#6
*JV6
#5
*JV5
#4
*JV4
#3
*JV3
#2
*JV2
#1
*JV1
#0
*JV0
*JV15G011 *JV14 *JV13 *JV12 *JV11 *JV10 *JV9 *J V8
RTG019
+J8G100 +J7 +J6 +J5 +J4 +J3 +J2 +J1
-- J 8G102 -- J 7 -- J 6 -- J 5 -- J 4 -- J 3 -- J 2 -- J 1
Manual rapid traverse
selection signal
RT<G019#7>
Signal address