B--63003EN--1/02
9. SPINDLE SPEED FUNCTION
900
#7 #6 #5 #4 #3 #2 #1 #0
3701 SS2
[Data type] Bit type
NOTE
After setting this parameter, turn the power off then on again
so that the setting will take effect.
SS2 Under serial spindle control, the second serial spindle is:
0: Notused.
1: Used.
NOTE
1. This parameter is enabled when the spindle serial output
option is selected, and bit 1 (ISI) of parameter No. 3701 is
set to 0.
2. If the spindle synchronous control option is selected, this
parameter is automatically set at power --on. Once this
parameter is set, the following is possible:
1 Confirmation of connection with, and communication
with the second serial spindle amplifier
2 Control of the second spindle when asynchronous
control is used (SIND2)
Before the simple spindle synchronous control function can
be used, two serial spindles must be connected. This
means that the user must set this parameter beforehand; it
is not set automatically.
When this parameter is set, the serial spindle parameter for
the second spindle must also be set.
#7
SPK4800
#6 #5 #4 #3 #2 #1 #0
[Data type] Bit
NOTE
To put this parameter setting in effect, switch the power off
then back on again.
SPK Specifies what is to be used as the parking signal for spindle simple
synchronization control.
0 : PKESS1 <G122#6> (first spindle) and PKESS2 <G122#7> (second
spindle)
1 : PKESS1 <G031#6> (first spindle) and PKESS2 <G031#7> (second
spindle)
Parameter