4. REFERENCE POSITION ESTABLISHMENT
B--63003EN--1/02
388
[Classification] Output signal
[Function] Notify the system that the tool is at the floating reference position on a
controlled axis.
A floating reference position return end signal is provided for each axis.
The number appended to each signal name indicates the number of the
controlled axis.
1 : Floating reference position return end signal of 1st axis
2 : Floating reference position return end signal of 2nd axis
3 : Floating reference position return end signal of 3rd axis
:
:
FRP 1
[Output condition] The signals are set to 1 in the following case:
· When the tool is positioned to within the in--position area after floating
reference position return (G30.1)
These signals are set to “0” when:
· The tool is moved from the floating reference position
· An emergency stop is applied.
· A servo alarm is raised.
#7
FRP8F116
#6
FRP7
#5
FRP6
#4
FRP5
#3
FRP4
#2
FRP3
#1
FRP2
#0
FRP1
Signal
Floating reference
position return end
signal FRP1 to FRP8
<F116>
Signal address