B--63003EN--1/02
7. FEEDRATE CONTROL/ACCELERATION
AND DECELERATION CONTROL
547
In circular cutting with an inward offset, the actual feedrate for a specified
feedrate (F) becomes as follows:
F ×
Rc
Rp
Rc: Radius of the path of the cutter’s center
Rp: Programmed radius
As the actual feedrate becomes the value obtained from the above
equation, the specified rate F can be achieved on the program path.
Programmed
path
Cutter center
path
Rc
Rp
If Rc is too samall in comparison with Rp so that
Rc
Rp
≐0, the cutter will
stop. To prevent this, the minimum deceleration ratio (MDR) is set.
When
Rc
Rp
≐0,
the actural rate becomes as follows:
F (MDR)
1711 Angle (θp) to recognize the inner corner in automatic override
[Data type] Byte
[Unitofdata] Degree
[Valid data range] 1 to 179 (standard value = 91)
Set the angleto recognize the inner corner when automatic corneroverride
is performed for the inner corner
1712 Amount of automatic override for an inner corner
[Data type] Byte
[Unitofdata] %
[Valid data range] 1 to 100 (standard value = 50)
Set inner cornerautomatic override value when automatic corner override
is performed.