B-65395EN/01 HANDLING 3.PERIPHERAL EQUIPMENT CONTROL
- 111 -
3.8.4 Parameter
No #7 #6 #5 #4 #3 #2 #1 #0
005 ABSPS LDM
[Size] 1 byte (bit type)
[Standard value] 0
ABSPS With the response data read function, the host and servo amplifier
module are:
0 : Not synchronized.
1 : Synchronized. (Even during movement on axes, the host can read
correct position data.)
LDM Motor current value output in response data (Xx+3 to Xx+6) is:
0 : Disabled.
1 : Enabled.
No
020 Specification of the contents of response data (PHOUT)
[Size] 1 byte
[Standard value] 3
PHOUT As response data (Xx+3 to Xx+6):
0 : No data is output.
1 : ATC or point number data is output.
In the case of ATC cycle or point positioning:
2 : Machine coordinates are output in real time.
3 : Workpiece coordinates are output in real time.
4 : A motor current value is output. The motor current value 6554
represents the maximum current value of the servo amplifier
module.
5 : Measurement data (workpiece coordinates) obtained when a skip
signal is input is output.
6 : An actual feedrate is output in real time.
[Unit of data] 10
N
User-specified unit/MIN (N:Parameter No. 021)
7 : An actual speed is output in real time.
[Unit of data] min
-1
8 : A torque command is output in real time. The maximum value of
a torque command is 6554.
The least significant bit is a signal indicating whether the torque
limit is reached.
Least significant bit =
0: The torque limit is not reached.
1: The torque limit is reached.