B-65395EN/01 APPENDIXD.POWER MATE CNC MANAGER FUNCTIONS
- 319 -
D.2.3 Parameters
#7 #6 #5 #4 #3 #2 #1 #0
0960 PPE PMN MD2 MD1
[Input type] Setting input
[Data type] Bit path
# 1 MD1
# 2 MD2 The slave parameters are input from and output to either of the
following devices:
Parameter MD2 Parameter MD1 I/O destination
0 0 Program memory
0 1 Memory card
# 3 PMN The Power Mate CNC manager function is:
0: Enabled.
1: Disabled. (Communication with the slave is not performed.)
# 4 PPE Setting slave parameters using the Power Mate CNC manager:
0: Can always be performed regardless of the setting of PWE.
1: Follows the setting of PWE.
#7 #6 #5 #4 #3 #2 #1 #0
0961 PMO
[Input type] Parameter input
[Data type] Bit
# 3 PMO The O number of a program for saving and restoring the I/O LINK β
parameter is set based on:
0: Group number and channel number
1: Group number only
8760 Program number of data input/output (Power Mate CNC manager)
[Input type] Setting input
[Data type] 2-word path
[Valid data range] 0 to 99999999
This parameter sets the program numbers of programs to be used for
inputting and outputting slave data (parameters) when the Power Mate
CNC manager function is used.
For a slave specified with I/O LINK channel m and group n, the
following program number is used:
Setting + (m - 1) × 100 + n × 10
If the setting is 0, the parameters of the slave specified with channel 1
and group 0 cannot be input from or output to the CNC memory
because the program number is set to 0. The parameters can be input
from and output to a memory card.