B-66284EN/01 2.DEVELOPMENT OF CUSTOM SCREEN
- 119 -
- Action
No Action:
Check this check box to disable the lamp control function.
The control can be placed on the form, but can be disabled, in
which case the display is embedded.
Set the lamp image for no action set in the Image tab.
Watch PMC Area:
Specify a type of address for the PMC signal that turns on and
off the lamp. The following areas can be specified:
R, D, K, X, Y, G, F, E(PMC-SB7)
Watch Address:
Specify a monitor PMC signal address.
Watch Bit:
Specify the bit position of the signal address above by using a
number from 0 to 7.
Use Blink:
Check this check box to cause the lamp to blink.
Blink Signal Area
Specify the type of the address of the PMC signal for specifying
the blinking of the lamp. The following areas can be specified.
R, D, K, X, Y, G, F, E(PMC-SB7)
Blink Signal Address:
Specify a monitor PMC signal address.
Blink Signal Bit:
Specify the bit position of the signal address above by using a
number from 0 to 7.