B-66284EN/01 2.DEVELOPMENT OF CUSTOM SCREEN
- 133 -
Address:
Specify an output signal address.
Bit:
Specify the bit position of the signal above by using a number
from 0 to 7.
Bit Pattern:
[0:0] Outputs 0 (LOW) to a bit specified for output.
[1:1] Outputs 1 (HIGH) to a bit specified for output.
[2:Revers] Outputs a bit specified for output after reversion of 0/1.
- Detail[Momentary]-[Data Set]
Specify which value to be output to which PMC area when the switch
is on. The size of output data is word.
PMC Area:
Specify a type of address for a PMC signal to be output. The
following areas can be specified:
R, D, K, X, Y, G, F, E(PMC-SB7)
Address:
Specify an output signal address.
Word:
Specify a value from -32767 to +32767.
- Detail[5:Alternate]-[Data Set]
[ON Action], [OFF Action]
Specify separately [ON Action] to be executed when the switch
makes a transition from OFF to ON, and [OFF Action] to be
executed when the switch makes a transition from ON to OFF.
PMC Area:
Specify a type of address for a PMC signal to be output. The
following areas can be specified:
R, D, K, X, Y, G, F, E(PMC-SB7)