2.DEVELOPMENT OF CUSTOM SCREEN B-66284EN/01
- 200 -
2.3.14
Numeral/Character String Indication Control
This control is used to display character data or numerals in a PMC
register or to call character data or numerals from the NC with an FP
function for display. As a special application, a setting can be made
which calls character data or a numeral with an FP function but does
not display the called data or numeral.
Property Pages
- General
Object ID:
Object ID managed in the form. This ID is automatically
assigned. The user cannot change this ID.
X, Y:
Set the coordinates of the upper-left corner of the
numeral/character string indication control.
Width, Height:
Set the width and height of the numeral/character string
indication control.