2.DEVELOPMENT OF CUSTOM SCREEN B-66284EN/01
- 122 -
Data Length:
If specifying 1:PMC (big or small comparison) for Type, specify
the data length of the PMC area specified with the signal area
and the signal address.
0: 1 Byte (Signed)
1: 1 Byte (Unsigned)
2: 2 Byte (Signed)
3: 2 Byte (Unsigned)
4: 4 Byte (Signed)
5: 4 Byte (Unsigned)
This option is not used if 0:PMC (bit) is specified for Type.
Use Blink Signal:
Check this box to use blinking in the numeral indication section.
This option takes effect if 1:PMC (big or small comparison) is
specified for Type.
Blink Signal Area:
Specify the type of the address of the PMC signal used to specify
the blinking in the numeral indication section. The following
areas can be specified:
R, D, K, X, Y, G, F, E(PMC-SB7)
This option takes effect if 1:PMC (big or small comparison) is
specified for Type.
Blink Signal Address:
Specify the address of the blink signal.
This option takes effect if 1:PMC (big or small comparison) is
specified for Type.
Blink Signal Bit:
Specify the bit position of the signal address above by using a
number 0 to 7.
This option takes effect if 1:PMC (big or small comparison) is
specified for Type.
Light Color #6 to #0:
Specify the ON color corresponding to each of the bits.
Character Color #6 to #0:
Specify the numeral indication character color corresponding to
each of the bits.
Change Beginning Value:
Specify the value whose magnitude is to be compared with that
of the value of the PMC area specified with the signal area and
the signal address. If the value of the PMC area specified with
the signal area and the signal address exceeds the value specified
here, the lamp turns on in the ON color corresponding to the
change beginning value.
This option takes effect if 1:PMC (big or small comparison) is
specified for Type.