B-66284EN/01 2.DEVELOPMENT OF CUSTOM SCREEN
- 49 -
(4) Signal Display/OP ratio
The signal display function displays signal information set in the
button control (Only the one that the shortcut key is defined can be
displayed for non-touch panel display unit) and the lamp control (The
lamp cannot be displayed for non-touch panel display unit) while
displaying the screen made with FANUC PICTURE in CNC.
The signal set in ‘The signal display is used’is turned on, and the
control on the custom screen is displayed to following signal
information while the operator is touching (The MDI key is operated
for non-touch panel display unit).
Moreover, the touched control does not operate when the signal set in
‘The operation is invalidated’is turned on at the same time and only
the signal display is done. When this signal is turned on, the screen
switch button operation is not done. Therefore, it is not possible to
switch from the operation panel screen to other screens including the
CNC screen. Please install the switch of this signal outside or make
the ladder such as turning off this signal automatically when the fixed
time passes by the timer for this measures.