2.DEVELOPMENT OF CUSTOM SCREEN B-66284EN/01
- 218 -
Secure 1byte, Secure 2byte: (use byte)
Select the size of the number area.
If Secure 1byte is selected, a text number of 1 to 255 can be
specified.
If Secure 2byte is selected, a text number of 1 to 65535 can be
specified.
File Name:
Specify a text number and the name of the spreadsheet file
describing the message character string.
Edit button:
Click this button when a file (~.vts) for setting character strings
used to create a message to be displayed is edited. For the
method of editing, see “Text File Configuration and Editing” in
the text character string display control.
Interface with the PMC area
For the number interface
A text message is displayed on the operator’s panel via the 1- or
2-byte text number report interface, using the R or D or
E(PMC-SB7)area of the PMC. If the text number is zero, the
character previously displayed will be erased. Subsequently, the
system monitors for a number change, and displays a text
message only if a change is made. The system monitors for a
number change periodically and, therefore, a number change
must be retained for 500 msec or longer. If a change cannot be
detected, the message cannot be displayed.