OPERATION
B–63664EN/02
15. LASER FUNCTION
785
b. With the option for additional cutting condition registration
E ;
The number of cutting data set (1 to 30)
The number of piercing data set (101 to 110)
4) Auxiliary data groups are specified from data items in cutting data
groups. It is impossible to specify auxiliary data groups directly with
address E.
Piercing data consists of the items listed below.
For the operation of piercing, see Section 18.2, “PIERCING
FUNCTION”, in Part II, “PROGRAMMING”.
1) Setting items
Data item Setting range Unit
Peak power 0 to 9999 W
Initial frequency 5 to 2000 Hz
Initial duty 0 to 100 %
Step frequency 0 to 2000 Hz
Step duty 0 to 99 %
Step time 0 to 9.999 Sec
Step number 0 to 99
Piercing time 0.001 to 999.999 Sec
Assist gas pressure 0 to 9.99 MPa
Assist gas select 1 to 7
Gas settling time 0 to 9.9 Sec
Reference displace –9.999 to 9.999 mm
2) Size
A group consists of three sets, each consisting of the above items,
when the option for additional cutting condition registration is not
provided, or a group consists of ten sets when the option for additional
cutting condition registration is provided.
3) Calling method
If a piercing data set number is specified with address E in a program,
the data set with the specified number is read as active data.
E ;
The number of piercing data set (101 to 103
(*1)
, 101 to
110
(*2)
)
*1 Without the option for additional cutting condition registration
*2 With the option for additional cutting condition registration
Items of cutting
condition data groups
D Piercing data group