3.TROUBLESHOOTING AND ACTION TROUBLESHOOTING B-65285EN/03
- 94 -
3.2.4 Alarm Code 6
(1) Meaning
Inverter: overheat
(2) Cause and troubleshooting
(a) Check that the motor is being used at or below its continuous
rating.
(b) Check that the cooling capacity of the cabinet is sufficient
(inspect the fans and filters).
(c) Check that the ambient temperature is not too high.
(d) Be sure to push the faceplate (control printed-circuit board)
as far as it will go.
(e) Replace the SVM.
3.2.5 Alarm Code F
(1) Meaning
Innverter: cooling fan stopped of the radiator
(2) Cause and troubleshooting
(a) Check whether there is any foreign material in the fan.
(b) Be sure to push the faceplate (control printed-circuit board)
as far as it will go.
(c) Check that the fan connector is attached correctly.
(d) Replace the fan.
(e) Replace the SVM.
3.2.6 Alarm Code P
(1) Meaning
Communication error between amplifier and module
(2) Cause and troubleshooting
(a) Check the connector and cable (CXA2A/B).
(b) Replace the control printed-circuit board.
(c) Replace the SVM.