4. SERVO FUNCTION DETAILS B-65150E/04
− 152 −
(Related parameters)
#7 #6 #5 #4 #3 #2 #1 #0
1957
−
TDOU
2015 1015
TDOU (#5) When an estimated disturbance value is output to the check board:
1: The estimated disturbance value is output to the torque command
output channel.
0: The torque command output channel is based on the standard
specifications.
[Setting value] Set 1 when an estimated disturbance value is measured.
1862
−
Observer gain
2050 1050
[Setting value] No change is required.
1863
−
Observer gain
2051 1051
[Setting value] No change is required.
* When setting an observer gain, follow the settings of other
functions (observer, abnormal load detection). When the
two-stage backlash acceleration function is used, the settings
need not be changed.
1859
−
Observer parameter (POA1)
2047 1047
[Setting value] Adjusted value (Make an adjustment according to steps <4> to <6> in
(3) in Subsec. 4.12.1.)
1980
−
Torque offset parameter
2087 1087
[Setting value] Adjusted value (If the center of an estimated disturbance value does not
become zero on an axis such as the gravity axis, make an adjustment
according to step <7> in (3) in Subsec. 4.12.1.)