B-65150E/04 APPENDIX
− 347 −
A. DEFFERENCES BETWEEN THE PARAMETERS
FOR THE Series 15-A AND Series15-B (15i-A)
A
DIFFERENCES BETWEEN THE PARAMETERS
FOR THE Series 15-A AND Series 15-B (15
i
-A)
(1) Overview
The Series 15-A and Series 15-B incorporate servo software of
different series. For some servo functions, they use different parameter
numbers and setting methods.
The servo parameters for the Series 15i-A are the same as for the Series
15-B.
The Series 15-A, 15-B, and 15i-A are applicable to the following servo
ROMs that support the α servo-mechanism:
NC model
Series of servo ROM applicable to the
α servo-mechanism
Series 15-A Series 9041 (supporting dual position feedback)
Series 9046 (supporting standard and high-speed positioning)
Series 15-B Series 9060 (320C25 servo module)
Series 9070 (320C51 servo module)
Series 9080 (320C52 servo module)
Series 9081 (320C52 servo module)
Sereis 15i-A
Series 90A0 (320C543 servo card)
The parameter numbers and setting methods differ for the following
servo functions:
<1> Dual position feedback function <2> High-speed positioning function
<3> Feed-forward function <4> Machine velocity feedback function
<5> Functions for α motor <6> Function for extending position
gain setting range
(2) Details
<1> Dual position feedback function (See Subsec. 4.5.4.)
The Series 15-A and 15-B (15i-A) use different numbers for the
parameter that enables this function.
For other parameters related to this function, however, the three
systems use the same numbers.
Function Series 15-A (Series 9041) Series 15-B, 15i-A
Enable bit No. 1955 #7 No. 1709 #7
Maximum amplitude
Conversion coefficient
(numerator/denominator)
Primary delay time
constant
Zero width
No. 1861
No. 1971/No. 1972
No. 1973
No. 1974