3/5
Descri
tionDesigDateEd
01
00.07.06
Sonoda Newly designed
Tandem Disturbance
Elimination Control
Specification Manual
B-65150E/04--0012
4
.
Setting parameters
#7 #6 #5 #4 #3 #2 #1 #0
1709(FS15)
TANDMP
2019(FS16)
TANDMP(#1) Tandem Disturbance Elimination Control function
(
Set this parameter for Main-axis only
)
0 : Invalid
1 : Valid
#7 #6 #5 #4 #3 #2 #1 #0
1952(FS15)
VFBAVE
2008(FS16)
VFBAVE(#2) Velocity Feedback Averaging function
(
Set this parameter for Main-axis only
)
0 : Invalid
1 : Valid
[Setting method] Standard is set to zero. Velocity Feedback Averaging function is only
effective with the machine having a specific stiffness. This function isn’t usually applied
together with Tandem Disturbance Elimination Control function. If this function is valid, both
Integral gain Ki and proportion gain Kc must be set to zero.
(Note) In case of series 90B3, 90B7, this function bit is #6 of Sub-axis.
1721(FS15)
2036(FS16)
Proportion gain Kc
Dam
in
com
ensation
ain Kc
(
Set this parameter for Main-axis only
)
[Valid data range] 0 to 32767 (0 < Kc < 0.5)
[Standard setting] 0
This parameter is used with the machine having large friction.
Velocity fbm
Velocity fbs
+
-
Phase
com
ensatio
+
+
2036(S)
2325(S)
2325(S)
2036(S)
Tandem Disturbance
Tandem DisturbanceTandem Disturbance
Tandem Disturbance
Elimination Control
Elimination ControlElimination Control
Elimination Control
Tcmd(m)