B-65150E/04 4. SERVO FUNCTION DETAILS
− 241 −
1732
−
Conversion coefficient for the number of feedback pulses (SBPDNL)
2121
−
The value specified in this parameter is used to divide the number of
velocity pulses and the number of position pulses to produce a value
not greater than 32,767. For this parameter, set as small a value as
possible.
[Typical setting] 100 or 1,000
1876
−
Number of velocity pulses (PULCO)
2023
−
Set the following:
Number of feedback pulses from
a separate velocity detector per motor revolution
SBPDNL
1891
−
Number of position pulses (PPLS)
2024
−
Set the following:
Number of feedback pulses from
a separate position detector per motor revolution
SBPDNL
#7 #6 #5 #4 #3 #2 #1 #0
1804
−
PLC0
2000
−
PLC0 (#0) The number of velocity pulses and the number of position pulses are:
0: Used as is ← To be set
1: Used after multiplication by 10
Example of setting
When a separate velocity detector of 3,000,000
pulses/revolution and separate position detector of
1,000,000 pulses/revolution are used (Series 15-B)
No. 1807#3 = 1 (first axis, second axis)
No. 1815#1 = 1 (first axis, second axis)
No. 1953#0 = 1 (second axis)
No. 1884#3 = 1 (first axis)
No. 1709#4 = 1 (first axis)
No. 1732 = 1,000
No. 1876 = 3,000,000/1,000 = 3,000
No. 1891 = 1,000,000/1,000 = 1,000
No. 1804#0 = 0 (first axis)