4. SERVO FUNCTION DETAILS B-65150E/04
− 278 −
4.19 SERVO CHECK BOARD OPERATING PROCEDURE
(1) Overview
The servo check board enables digital control values used in a digital
servo section to be observed from the outside. The digital control
values can be observed in either analog or digital form. Analog outputs
can be observed directly with an oscilloscope, and digital outputs can
be observed with a personal computer.
(2) Servo check board configuration
The following table lists the signals that can be observed with the servo
check board, and the number of supported axes.
Table 4.19 (a) Servo check board specification
Name Specification Output interface
Number of
supported
axes
Number of
output
channels
A A06B-6057-H630 Analog and digital 8 4 (optional)
B A06B-6057-H620 Digital only 4 4 (optional) (*)
C A06B-6057-H602 Analog only 2 8 (fixed) (*)
* Servo check board A (one-piece analog/digital type) is upward-
compatible, that is, can be replaced, with digital check board B and
analog check board C.
The method for connecting the servo check board with a CNC varies
with the type of the CNC.
The following table lists the ordering information for adapters and
cables required to connect the check board.
Table 4.19 (b) Adapters and cables required to connect the servo check board to each CNC
CNC Required adapters and cables Ordering information
Series 15i, 16i, 18i, 21i,
Power Mate i
Adapter board + dedicated i series cable
Straight cable
A02B-0236-K822
A06B-6050-K872
Series 15-B, 16, 18, 20,
21-TB, 21-MB
Adapter board (required only for check board C)
Straight cable
A02B-0120-C211
A06B-6050-K872
Series 0-C, 15-A, 21-TA,
Power Mate
Reverse-insertion-prevented cable A06B-6050-K871
Power Mate - H Straight cable A06B-6050-K872
Power Mate - E Dedicated Power Mate-E adapter board
Reverse-insertion-prevented cable
A02B-0168-K201
A06B-6050-K871
β amplifier with I/O link Dedicated adapter board + cable
Reverse-insertion-prevented cable
A06B-6093-K021
A06B-6050-K871