4/5
Descri
tion
Design.
DateEd.
00.10.03
.
o.
.
Ihara Newl
desi
ned
Notice of the update of Digital
Servo Software 90B0 series
B-65150E/04-013
FANUC LTD
b) When unexpected disturbance detection performed separately for cutting and rapid
traverse is used with No.1800#3=1, please enable the following bit, too.
#7 #6 #5 #4 #3 #2 #1 #0
2603 (FS15
i
)ABT2
2215 (FS16
i
)
ABT2(#7) 1: Regardless of No.1800#3, ABTSH is used for cutting, and
ABTSHG0 is used for rapid traverse.
(A table of used alarm level)
FS16
i
2215#7 No.1800#3 mode No.2104 No.2142
cutting O
rapid traverse O00
JOG, handle O
cutting O
rapid traverse (*1) O01
JOG, handle O
cutting O
rapid traverse O10/1
JOG, handle O
FS15
i
2603#7 No.1800#3 mode No.1997 No.1765
cutting O
rapid traverse O00
JOG, handle O
cutting O
rapid traverse (*1) O01
JOG, handle O
cutting O
rapid traverse O10/1
JOG, handle O
(*1) Because of the specification difference between FS15
i
and FS16
i
, the different
alarm level is used at the mode JOG and handle when No.1800#3=1.