5. DETAILS OF PARAMETERS B-65150E/04
− 294 −
#7 #6 #5 #4 #3 #2 #1 #0
8X04 DLY0
1809
DLY0 (#6) The PWM dead zone is set to:
0: 8 µs
1: 16 µs
Always set this bit to 1 when using the S series servo amplifier, α series
large-size servo amplifier (SVMI-240, -360), and α series HV servo
amplifier.
#7 #6 #5 #4 #3 #2 #1 #0
8X05 SFCM BRKC FEED
1883
FEED (#1) The feed forward function is:
0: Not used
1: Used
⇒ See Subsecs. 4.6.1, 4.6.2, and
4.6.3.
Related parameters :
8X68 (Series 0-C) and 1961
(Series 15-A)
BRKC (#6) The vertical axis brake control
function is:
0: Not used
1: Used
⇒ See Sec. 4.10.
Related parameters :
8X83 (Series 0-C) and 1976
(Series 15-A)
SFCM (#7) The static friction compensation
function is:
0: Not used
1: Used
⇒ See Subsec. 4.6.6.
Related parameters :
8X03 (Series 0-C), 1808
(Series 15-A), 8X72 (Series 0-
C), 1965 (Series 15-A), 8X73
(Series 0-C), and 1966 (Series
15-A)
#7 #6 #5 #4 #3 #2 #1 #0
8X06 DCBE ACCF PKVE DBST FCBL
1884
FCBL (#0) Specifies whether to reflect backlash
compensation pulses to the position as
follows:
0: To reflect
1: Not to reflect
If this parameter is set to 1, quadrant
protrusions caused by backlash can be
reduced even in a closed loop system.
Generally, in a closed loop system,
backlash compensation is not set. If
FCBL is set to 1, however, protrusions
can be reduced without position
deviation.
⇒ See Subsecs. 4.6.4 and 4.6.5.