B-65150E/04 4. SERVO FUNCTION DETAILS
− 227 −
<2>-a When using A06B-6057-H620 (digital check board), set the
DIP switches on the check board as follows:
To measure an odd-numbered axis:
AXIS2: 1 (torque) AXIS1: 10 (phase)
To measure an even-numbered axis:
AXIS2: 3 (torque) AXIS1: 11 (phase)
<2>-b When using A06B-6057-H630 (one-piece analog/digital type),
set up the 7-segment LED digits on the check board as shown
below:
<3> To measure the activating phase angle, set the following
parameter.
1726
−
Parameter for internal data measurement
2115
−
Series 9080/D(04) and previous editions:
1456 (for both odd- and even-numbered axes)
Series 9080/E(05) and subsequent editions, Series 9081, and
Series 9090:
1328 (for both odd- and even-numbered axes)
Series 90A0:
704 for odd-numbered axis and 2752 for even-numbered axis
Steps <2> and <3> enable CH0 and CH1 of the SD software to be used
to measure the motor activating phase angle (CH0) and torque
command (CH1).
NOTE) Letter X stands for an axis
number specified in
parameter No. 1023.
Axis 2
1
0
A
0
A
1
A
2
A
3
A
0
A
1
A
2
A
3
Outputs for PIO-48W PC-Card Output to Analog Spindle
Input from JA8A
Data Type Setting
Axis4 Axis3 Axis2 Axis1
1: High 0: Low
CNB
A16B-2300-0170
xxxx xxxx
CN
CN11
CN13
CNSCNB CNB CNB
CNA1
0001 1010
DIP switch
Axis 2 Axis 1
1
0
A
0
A
1
A
2
A
3
A
0
A
1
A
2
A
3
5X
1X
CH1
Phase
CH2
Torque