4. SERVO FUNCTION DETAILS B-65150E/04
− 206 −
(3) Parameter adjustment methods
<1> Connect a check board to enable the motor velocity and torque
command to be observed with an oscilloscope or personal
computer.
The measurement channels of the check board should be as
follows:
Digital and analog (for A06B-6057-H630): Channel 1
Digital (for A06B-6057-H620)
Odd-numbered axis specified in parameter No. 1023: DIP
switch 0001
Even-numbered axis specified in parameter No. 1023: DIP
switch 0011
Analog (for A06B-6057-H602)
Odd-numbered axis in parameter No. 1023: CH2
Even-numbered axis in parameter No. 1023: CH4
(See Sec. 4.19 for detailed descriptions about how to use the
check board.)
<2> Switch on the NC.
<3> Enable the abnormal-load detection function.
#7 #6 #5 #4 #3 #2 #1 #0
1958
−
ABNT
2016 1016
ABNT (#0) Specifies whether to enable the abnormal-load detection function as
follows:
1: To enable
0: To disable
<4> Also set the following parameter bit.
#7 #6 #5 #4 #3 #2 #1 #0
1957
−
TDOU
2015 1015
TDOU (#5) Specifies whether to output an estimated disturbance value to the check
board as follows:
1: To output an estimated disturbance value to the torque command
output channel
0: The torque command output channel is used according to the
standard specification.
Setting the above parameter causes an estimated disturbance value,
rather than the torque command, to be output to the check board.
Moreover, be sure to set also the following parameters.