B-65150E/04 4. SERVO FUNCTION DETAILS
− 207 −
[For Series 9080, 9090, and 90A0]
(This function is supported in the Series 9080/G(07) and subsequent
editions, Series 9090/C(03) and subsequent editions, and Series
90A0/A(01) and subsequent editions.)
#7 #6 #5 #4 #3 #2 #1 #0
1740
−
IQOB
2200 1200
[For Series 9065 and 9066]
(This function is supported in the Series 9065/A(01) and subsequent
editions, and Series 9066/G(07) and subsequent editions.)
#7 #6 #5 #4 #3 #2 #1 #0
−
IQOB
2009 1009
IQOB Specifies whether to eliminate influence of control voltage saturation
when estimating disturbance, as follows:
1: To eliminate influence of control voltage saturation when
estimating disturbance
0: Not to take influence of control voltage saturation when estimating
disturbance into consideration
Set up the parameters related to the observer.
1862
−
Observer gain
2050 1050
[Typical setting] 956 → To be changed to 3559.
1863
−
Observer gain
2051 1051
[Typical setting] 510 → To be changed to 3329.
NOTE
When this function is used together with the observer
(bit 2 of Nos. 1808, 2003, and 1003 = 1), keep them at
the typical setting.
This setting delays the rising of the estimated
disturbance value slightly, but it does not pose any
problem in almost any case.