B-65150E/04 4. SERVO FUNCTION DETAILS
− 197 −
4.11 STOP DISTANCE REDUCTION FUNCTION
The functions described below prevent the tool from colliding with the
machine or workpiece by reducing the distance required for the motor
to come to a stop if a usual emergency stop condition occurs or if a
separate detector disconnection alarm, overheat alarm, or OVC alarm
is issued.
4.11.1 Emergency Stop Distance Reduction Function Type 1
(1) Overview
This function reduces the stop distance by resetting the velocity
command for a servo motor to 0 at a position where an emergency stop
signal is detected for the servo motor.
(2) Series and editions of applicable servo software
Series 9041/A(01) and subsequent editions (Series 0-C, 15-A)
Series 9046/B(02) and subsequent editions (Series 0-C, 15-A)
Series 9060/L(12) and subsequent editions (Series 15-B, 16-A, 18-A,
20, 21, Power Mate)
Series 9066/A(01) and subsequent editions (Series 20, 21, Power Mate)
Series 9070/C(03) and subsequent editions (Series 15-B, 16-B, 18-B)
Series 9080/A(01) and subsequent editions (Series 15-B, 16-C, 18-C)
Series 9081/C(03) and subsequent editions (Series 15-B, 16-C, 18-C)
Series 9090/A(01) and subsequent editions (Series 16i, 18i, 21i)
Series 90A0/A(01) and subsequent editions (Series 15i, 16i, 18i, 21i)
(3) Setting parameters
[Parameter setting for other than the Series 904x (Series 15-B, 15i, 16,
18, 21)]
#7 #6 #5 #4 #3 #2 #1 #0
1959
−
DBST
2017
−
DBST (#0) Specifies whether to enable emergency stop distance reduction
function type 1 as follows:
1: To enable
0: To disable
[Parameter setting for the Series 9046 and 9041 (Series 0-C, 15-A)]
#7 #6 #5 #4 #3 #2 #1 #0
1884 8X06 DBST
− −
DBST (#1) Specifies whether to enable emergency stop distance reduction
function type 1 as follows:
1: To enable
0: To disable