D. FUNCTION-SPECIFIC SERVO PARAMETERS APPENDIX B-65150E/04
− 366 −
✰ : Parameters set up automatically or cleared at
initialization
Parenthesized parameters : Common parameters that are also used for
other functions
Parameter number
Series 15
Series 16,
18, 20, 21,
Power Mate
Power
Mate-E
Meaning
[Shape-error suppression functions]
[Backlash acceleration functions]
1851 1851 − Backlash compensation
1884#0 2006#0 − 1: Does not reflect the backlash compensation in positions.
✰
→ 4.6.4 to
4.6.5
1808#5 2003#5 − Backlash acceleration function
✰
1860 2048 − Backlash acceleration amount
✰
1964 2071 − Period during which backlash acceleration remains effective
✰
1953#7 2009#7 − Backlash acceleration stop
✰
1975 2082 − Timing at which the backlash acceleration is stopped
✰
1953#6 2009#6 − 1: Enables the backlash acceleration function during
cutting feed only.
✰
→ 4.6.4
1957#6
(1808#5)
2015#6
(2003#5)
−
Two-stage backlash acceleration function
(The backlash acceleration function is also enabled.)
✰
(1860) (2048) − Stage 1 acceleration amount
✰
1987 2094 − Stage 1 acceleration amount from negative direction to
positive direction
✰
1760 2137 − Stage 1 acceleration override
1975 2082 − Stage 2 start/end parameter
✰
1982 2089 − Stage 2 end scale factor
✰
1724 2039 − Stage 2 acceleration amount
1790 2167 − Stage 2 offset
1725 2114 − Stage 2 acceleration override
1960#2 2018#2 − The format of the stage 2 acceleration override is changed.
1953#6 2009#6 − 1: Enables backlash acceleration only during cutting feed.
✰
→ 4.6.5
✰
1883#7
(1808#5)
2005#7
(2003#5)
−
Static friction compensation function
(The backlash acceleration function is also enabled.)
✰
(1964) (2071) 1071 Compensation count
✰
1965 2072 1072 Static friction compensation
✰
1966 2073 1073 Stop state judgement parameter
✰
(1953#7) (2009#7) 1009#7 Stop of static friction compensation
✰
1990 2097 1097 Parameter for stopping static friction compensation
✰
→ 4.6.6
[Overshoot compensation functions]
1808#6 2003#6 1003#6 Overshoot compensation function
✰
1857 2045 1045 Velocity loop incomplete integral gain (PK3V)
✰
1970 2077 1077 Overshoot compensation counter
✰
1994 2101 − Overshoot compensation enable level
✰
1742#3 2202#3 − Overshoot compensation type 2
→ 4.7