B–62835EN/01
3. INPUT AND OUTPUT OF DATA
143
Power Mate memorized the following data.
Outputting the newest data I/O device while the CNC is rurnning
normally
(1) CNC paramter
(2) PMC parameter
(3) Custom macro variable values
(4) Tool compensation amount (offset data)
(5) Part program (Machining program, custom macro program)
(6) Ladder program
(7) Pitch error compensation value
Be sure that data output cannot be done in an alarm status.
Parameters required for output are as follows :
(To change parameters, set MDI mode or emergency stop status)
#7 #6 #5 #4 #3 #2 #1 #0Address
0000 ISO
#1 (ISO) 0 : Output with EIA code
1 : Output with ISO code (FANUC cassette)
Address
0020 Selection of I/O channel
0 : Channel 1 (JD5 of connector)
1 : Channel 1 (JD5 of connector)
1) I/O channel=0
Both I/O CHANNEL = 0 and I/O CHANNEL = 1 indicate channel
1. Separate parameters are, however, provided for each I/O
CHANNEL, for setting the baud rate, stop bit, etc.
#7 #6 #5 #4 #3 #2 #1 #0Address
0101 NFD ASI SB2
#7 (NFD) 0 : Feed is output when data is output.
1 : Feed is not output when data is output.
#3 (ASI)l0 : EIA or ISO code is used for input data.
1 : ASCII code is used.
#0 (SB2) 0 : No. of stop bits is 1.
l1 : No. of stop bits is 2.
(l : Standard setting)
Address
0102 pecification number of input/output device
0 RS–232–C (control codes DC1 to DC4 used)
1 Not used
2 FANUC Floppy cassette adapter F1
3 PROGRAM FILE Mate. FANUC Handy File ,FANUC Floppy
cassette adapter, FSP–H
4 Not used
5 Not used
6 FSP–G, FSP–H
3.2
INPUTTING/
OUTPUTTING DATA
3.2.1
Confirming the
Parameters Required
for Data input/Output