8. TROUBLESHOOTING
B–62835EN/01
296
(2) Interface type A
Power Mate
DV
RV
RV RLY
DV
Servo amplifier
JVn
–10
–20
*MCON
*DRDY
–10
–20
JVnB
Power on sequence (Power MateàServo amplifier)
= *Power supply unit failure
*Input fuse disconnection
= * Servo amp. alarm (1–9,b) *Emergency
stop signall (*ESP) Lack of 3–phase input
voltage
= *System alarm (ALM900∼973) *Servo alarm
(ALM400 to 417) *Emergency stop (*ESP)
= *SVF1 to 2 (Servo off signal)
Servo enable
Power ON
Position, velocity
control ready (*MCON)
Servo amp. ready (*DRDY)
NOTE
1 When a servo amplifier is shared by more than one Power
Mate, this alarm may occur in one of the Power Mate units
if *MCON is not generated in another Power Mate unit. Set
NOFVY (bit 2 of parameter No. 1803).
2 When a two–axis amplifier is used in a 2–path Power
Mate–D, this alarm may occur in one path of the Power
Mate–D unit if *MCON is not generated in the other path.
Set NOFVY (bit 2 of parameter No. 1803).
3 The non–generation of *MCON in another Power Mate or
another path of 2–path Power Mate may be due to an
emergency stop signal being input, follow–up after the
power is turned on, or the detach function being applied.