APPENDIX
B. ALARM LIST
B–62835EN/01
366
Number ContentsMessage
130 ILLEGAL AXIS OPERATION An axis control command was given by PMC to an axis controlled by
CNC. Or an axis control command was given by CNC to an axis
controlled by PMC. Modify the program.
131 TOO MANY EXTERNAL ALARM
MESSAGES
Five or more alarms have generated in external alarm message.
Consult the PMC ladder to find the cause.
132 ALARM NUMBER NOT FOUND No alarm No. concerned exists in external alarm message clear.
Check the PMC ladder.
133 ILLEGAL DATA IN EXT.
ALARM MSG
Small section data is erroneous in external alarm message or exter-
nal operator message. Check the PMC ladder.
139 CAN NOT CHANGE PMC
CONTROL AXIS
An axis is selected in commanding by PMC axis control.
Modify the program.
145 ILEGAL CONDITIONS IN POLAR
COORDINATE INTERPOLATION
A condition for starting or canceling polar coordinate interpolation
was incorrect. There is an error at plane selection (parameter No.
5460 or 5461 error). Correct the program or parameter setting.
190 ILLEGAL AXIS SELECT In the constant surface speed control, the axis specification is wrong.
(See parameter No. 3770.) The specified axis command (P) contains
an illegal value.
Correct the program.
199 MACRO WORD UNDEFINED Undefined macro word was used. Modify the custom macro.
200 ILLEGAL S CODE COMMAND In the rigid tap, an S value is out of the range or is not specified.
The maximum value for S which can be specified in rigid tapping is
set in parameter (No.5241 to 5243). Change the setting in the
parameter or modify the program.
201 FEEDRATE NOT FOUND IN RIGID
TAP
In the rigid tapping, no F value is specified.
Correct the program.
202 POSITION LSI OVERFLOW In the rigid tapping, spindle distribution value is too large.
203 PROGRAM MISS AT RIGID TAP-
PING
In the rigid tapping, position for a rigid M code (M29) or an S
command is incorrect. Modify the program.
204 ILLEGAL AXIS OPERATION In the rigid tapping, an axis movement is specified between the rigid
M code (M29) block and G84 (G74) block. Modify the program.
205 RIGID MODE DI SIGNAL OFF Rigid tapping signal (DGNG 061#1) is not 1 when G84 (G74) is
executed though the rigid M code (M29) is specified.Consult the PMC
ladder to find the reason the DI signal is not turned on.
Modify the program.
206 CAN NOT CHANGE PLANE (RIGID
TAP)
Plane changeover was instructed in the rigid mode.
Correct the program.
207 RIGID DATA MISMATCH The specified distance was too short or too long in rigid tapping.
224 RETURN TO REFERENCE POINT Reference position return has not been performed before the auto-
matic operation starts. Perform reference position return only when
bit 0 of parameter 1005 ZRN
X
is 0.
231 ILLEGAL FORMAT IN G10 OR L50 Any of the following errors occurred in the specified format at the pro-
grammable–parameter input.
1) Address N or R was not entered.
2) A number not specified for a parameter was entered.
3) The axis number was too large.
4) An axis number was not specified in the axis–type parameter.
5) An axis number was specified in the parameter which is not an
axis type.
233 DEVICE BUSY When an attempt was made to use a unit such as that connected via
the RS–232–C interface, other users were using it.
239 BP/S ALARM While punching was being performed with the function for controlling
external I/O units ,background editing was performed.
240 BP/S ALARM Background editing was performed during MDI operation.