6
6.2 Stand–Alone Type i Series Hardware
218
2) Setting of ROTARY SWITCH in case of connecting to CNC display unit
with PC functions
The power–on start sequence can be modified using rotary switch on
the board and short terminal (SW5) on CNC display unit with PC
functions.
setting of
rotary switch
short
terminal (SW5)
Description
0 OPEN Setting for maintenance.
The start menu is displayed. It is possible
to start boot and IPL from CNC display
unit with PC functions or PANEL i.
1 OPEN Setting for usual operation.
The start menu is not displayed.
It is impossible to start boot or IPL from
CNC display unit with PC functions or
PANEL i.
2 SHORT The CNC and CNC display unit with PC
functions or PANEL i are started indepen-
dently of each other without handshake.
* CNC
– CNC is available if CNC display unit
with PC functions or PANEL i is not
turned on or not connected. (Display
for CNC and MDI or Operation panel
etc. are needed to operate.)
– The start menu is not displayed if
CNC display unit with PC functions
or PANEL i is connected and turned
on.
* CNC display unit with PC functions or
PANEL i
– CNC display unit with PC functions
or PANEL i is available if CNC is not
turned on or not connected.
– Temperature management function of
CNC display unit with PC functions
or PANEL i doesn’t work. Please
make sure that the temperature is
proper for CNC display unit with PC
functions or PANEL i.
– The start menu is not displayed and
it is impossible to start boot or IPL
from CNC display unit with PC func-
tions or PANEL i if CNC is connected
and turned on.
This position must be used at mainte-
nance only.